SIMSEAL-310
EPOXY CONCRETE SEALER CLEAR


Description: A two component product, specifically formulated with an epoxy / polyamide resin to provide a water tight coating of low permeability for masonry and concrete surfaces.

Conformance: Conforms to military specification MIL-C-22750.

Principle Features:
Resists weathering, abrasion and hydrostatic pressure.
Resists dilute alkali, acids and mineral oils.
Seals minor cracks in concrete and has good water proofing properties.

Technical Data

Generic Type: Epoxy Polyamide
Finish: Clear, Glossy
Non-Volatile by Weight (Mixed) 52 1%
Volume SOlids (Mixed) 47.0 1%
Volatile Organic Compound (VOC) Mixed 3.75 Lbs/Gal.
Flash Point 61 F
Mixing Ratios (1:1) by volume
Pot Life @ 77 F: 3 hrs.
Weight/Gal. Mixed: 8.30 0.1
Recommended DFT: 1.5 - 2.0 mils
Theoretical Coverage @ 2.0 Mil DFT: Approx. 250 sq. ft.
Drying Time:
To Touch: 2 hours
To Topcoat: 16 hours
To Full Cure: 7 days
Thinner: R-300 epoxy thinner

Application Data:
Steam clean old concrete floors to remove all dirt, grease, oil and other foreign matter.
Allow it to dry overnight.
New concrete must be cured at least 14 days and must be free of surface moisture.
4. Apply to clean concrete only. Do not use on concrete containing membranes or curing agents.


Application:
Mix the resin component (part A) with the hardener component (part B) in equal proportions (by volume) thoroughly to form a homogenous clear solution. Do not change the mixing ratio. It is calculated at 1:1 or 1/2:1/2 by volume. Material once mixed should be used in 2-3 hours. Apply by a suitable roller, airless or conventional spray. Small areas may be brushed. Use R-300 epoxy thinner for a consistency adjustment if required. Provide thorough ventilation for proper curing of the sealer.

Safety Precautions:
(A) Use normal precautions such as gloves, facemasks.
(B) Adequate ventilation must be maintained.
(C) Explosion proof lights & electrical equipment.
(D) Non-Sparking shoes & tools for workers in area.
(E) This product contains flammable materials. Forbid all flames, smoking and welding in work area.
(F) Avoid breathing of vapor, contact with skin or eyes. If product comes in contact with skin or eyes, wash thoroughly with water and obtain medical attention.

Non-Warranty:
The technical data listed herein has been compiled for your convenience and guidance, and is based upon our experience and knowledge. However, since we have no control over the use of this information of this product, no warranty expressed or implied, is intended or given. Simco Coatings, Inc. assumes no responsibility whatsoever for coverage, performance, or any other damages, including injuries resulting from use of this information or of products recommended herein.